Description |
State |
|
Fuel Reduction Around Structure |
Required
on all structures |
|
Size Of Fuel Break |
30-100
feet: A 30 ft. break is required around all structures.
An additional 20 ft. must be added to structures
classified as “extreme” (& has fire-resistant roofing).
An additional 70 feet must be added (to the 30) when
a property is considered “extreme” and has flammable roofing
material. |
|
Dead Vegetation |
Remove
all |
|
Dry Grass Maximum Height |
4 inches |
|
Tree Pruning |
Maintain
plants in green condition, remove dead plant material and
ladder fuels, and arrange to minimize possibility of fire
transfer to adjacent vegetation |
|
Tree Thinning |
See Tree
Pruning* |
|
Shrubs |
See Tree
Pruning* |
|
Plant Species |
See Tree
Pruning* |
|
Vegetation Overhanging Structure |
Maintain
substantially free of dead vegetation |
|
Chimney & Stovepipe Clearance |
No
vegetation within 10 feet |
|
Firewood, Lumber Piles & Other
Flammables |
Move at
least 20 feet from structure, or fully enclose, during
months of fire season |
|
Exterior Decks |
Maintain
area beneath deck to be substantially free of firewood,
lumber, leaves, needles and similar flammable material |
|
Along Driveway |
Vegetation cleared to a height of 13 ½ ft, and a fuel break
which extends 10 ft on sides of driveway centerline
|
More On Fuels Management